NMEA-2000 (Maretron)
[hr top]
■ Display & Alarms
DSM250 Multi-Function Color Displays
● Sunlight Viewable
● Interprets and Displays all NMEA 2000® Data
● 16 User Configurable Favorites Screens
● Computed Fuel Management Displays
● Flush, Surface, or Gimbaled Mount
● Available in Black, Gray, and White Enclosures
● Configures Maretron Products
● Audio and Visual Alarms.
● Interprets and Displays all NMEA 2000® Data
● 16 User Configurable Favorites Screens
● Computed Fuel Management Displays
● Flush, Surface, or Gimbaled Mount
● Available in Black, Gray, and White Enclosures
● Configures Maretron Products
● Audio and Visual Alarms.
ALM100 Alarm Module
● Visual & Audible Alerts
– Triggered by N2KView or DSM250
● Loud Alarm(105dB)
– Mechanical Damper
– Distinctly Selectable Tone Patterns
● Green Operating LED and Red Alarm LED
● Mounts in Standard Electrical Box
● Waterproof
● Black or White Face Plate
– Triggered by N2KView or DSM250
● Loud Alarm(105dB)
– Mechanical Damper
– Distinctly Selectable Tone Patterns
● Green Operating LED and Red Alarm LED
● Mounts in Standard Electrical Box
● Waterproof
● Black or White Face Plate
[hr top]
■ Engine/Vessel Monitoring
J2K100 J1939 to NMEA 2000 Gateway
● Converts J1939 Data to NMEA 2000® Data for Display on Compatible Equipment (Furuno, Garmin, Maretron, Raymarine)
● Attaches to Any J1939 Engine, Transmission, or Genset
– Caterpillar, Cummins, Detroit Diesel, John Deere, Kohler, Northern Lights, Onan, Perkins, Steyr, Volvo Penta, Yanmar, etc.
● Converts Following Data
– AC Generator Current, Frequency, Voltage, Tach, Hours, Coolant Pressure & Temp, Oil Pressure & Temp, Fuel Rate, etc.
● Attaches to Any J1939 Engine, Transmission, or Genset
– Caterpillar, Cummins, Detroit Diesel, John Deere, Kohler, Northern Lights, Onan, Perkins, Steyr, Volvo Penta, Yanmar, etc.
● Converts Following Data
– AC Generator Current, Frequency, Voltage, Tach, Hours, Coolant Pressure & Temp, Oil Pressure & Temp, Fuel Rate, etc.
EMS100 Analog Engine Monitoring System
● Converts Analog Data to NMEA 2000® Digital Data
● Converts Following Data if Engine is Equipped with Sensors
– Tach, Hours, Water Temp, Oil & Boost Pressure, Volts, Trim
● Converts Engine Alarms if Engine is Equipped with Switches
– Fuel, Boost, Coolant Level & Temp, Oil Pressure, Exhaust Flow
● Plugs Directly into Engine Wiring Harnesses
● Used With or Without Analog Gauges
● Converts Following Data if Engine is Equipped with Sensors
– Tach, Hours, Water Temp, Oil & Boost Pressure, Volts, Trim
● Converts Engine Alarms if Engine is Equipped with Switches
– Fuel, Boost, Coolant Level & Temp, Oil Pressure, Exhaust Flow
● Plugs Directly into Engine Wiring Harnesses
● Used With or Without Analog Gauges
TLA100 Tank Level Adapter
● Adapts Resistive Tank Senders to NMEA 2000®(Royce, WEMA, etc.)
● American(240-30 ohm) or European(10-180 ohm) Standard Compatible
● Can be Calibrated for Irregular Shaped Tanks
● Can be Used With or Without Analog Gauges
● 16 Point Calibration
● Supports All Tank Types
– Fuel, Fresh Water, Waste Water, Live Well, etc
● American(240-30 ohm) or European(10-180 ohm) Standard Compatible
● Can be Calibrated for Irregular Shaped Tanks
● Can be Used With or Without Analog Gauges
● 16 Point Calibration
● Supports All Tank Types
– Fuel, Fresh Water, Waste Water, Live Well, etc
RAA100 Rudder Angle Adapter
● Adapts Resistive Rudder Senders to NMEA 2000®
● American(240-30 ohm) or European(10-180 ohm) Standard Compatible
● Can Be Used With or Without Analog Gauges
● End Point Calibration for Different Rudder Stop Angles
● American(240-30 ohm) or European(10-180 ohm) Standard Compatible
● Can Be Used With or Without Analog Gauges
● End Point Calibration for Different Rudder Stop Angles
[hr top]
■ Vessel Monitoring & Control PC SW/Interfacing
N2KView Vessel Monitoring & Control Software
● Server/Client Architecture
– Server Collects Information from NMEA 2000® Network and Distributes Data to Clients via Standard Internet Protocol
– Clients May Reside on Same Computer as Server, or Other Vessel Computers Networked via Ethernet, or Remote Computers via Internet Connection.
– Server Collects Information from NMEA 2000® Network and Distributes Data to Clients via Standard Internet Protocol
– Clients May Reside on Same Computer as Server, or Other Vessel Computers Networked via Ethernet, or Remote Computers via Internet Connection.
Vessel Monitoring & Control Software
● N2KView – Basic
– Vessel Monitoring Including Engines, Gensets, Tanks, Rudders, Navigation Instruments, Weather, Battery Monitor, DC/AC Parameters, Safety Systems, Security Systems, Etc.
● N2KView – Platinum
– Fuel Management
– Alerts (Alarms and Warnings)
– Electrical Switching*
– Local and Remote Video*
– Logging
– Vessel Monitoring Including Engines, Gensets, Tanks, Rudders, Navigation Instruments, Weather, Battery Monitor, DC/AC Parameters, Safety Systems, Security Systems, Etc.
● N2KView – Platinum
– Fuel Management
– Alerts (Alarms and Warnings)
– Electrical Switching*
– Local and Remote Video*
– Logging
USB100 NMEA 2000/USB Gateway
● Bridges Computer to NMEA 2000® Network
● Enables PC Based Vessel Monitoring Software(N2KView)
● Enables PC Based Navigation Software(Nobeltec, Rose Pointe, MaxSea, etc.)
● Enables PC Based Diagnostic Tools(N2KAnalyzer)
● One simple connection from PC to NMEA 2000®
● Enables PC Based Vessel Monitoring Software(N2KView)
● Enables PC Based Navigation Software(Nobeltec, Rose Pointe, MaxSea, etc.)
● Enables PC Based Diagnostic Tools(N2KAnalyzer)
● One simple connection from PC to NMEA 2000®
[hr top]
■ Cables and Connectors
Cables and Connectors
● Simple Trunk & Drop Line Topology Connects all NMEA 2000® Equipment
● Single Drop Line Allows Component Connect or Disconnect Under Power
● Cable Includes Power and Ground Up to 1 Amp per Product
● Keyed Connectors Error Free Hook Up
● Screw Thread Connectors Eliminates Inadvertent Disconnects
● Waterproof Connection System Works Even While Submerged
● 3 Independent Shields For Reduced EMI
● Gold Plated Terminals for Reliable Connections
● Nickel Plated Brass Connectors Ideally Suited to Marine Environment
● Cable and Connector Approvals
– NMEA 2000, IEC 61162-3, Lloyds
● 3 Cable Sizes(Micro, Mid, Mini)
– Micro and Mid Use Same Connectors
– All Use Same 5 Wire Color Coding
– All Cabling Systems are 12 Volt
– Micro Cable
– Small/Short Networks(<10 Nodes)
– Rated to 4 Amps
– Voltage Drops of Concern- Mid Cable(ABYC Approved)
– Mid/Large Networks
– Rated to 4 Amps- Mini Cable(ABYC Approved)
– Large Networks
– Rated to 8 Amps.
● Single Drop Line Allows Component Connect or Disconnect Under Power
● Cable Includes Power and Ground Up to 1 Amp per Product
● Keyed Connectors Error Free Hook Up
● Screw Thread Connectors Eliminates Inadvertent Disconnects
● Waterproof Connection System Works Even While Submerged
● 3 Independent Shields For Reduced EMI
● Gold Plated Terminals for Reliable Connections
● Nickel Plated Brass Connectors Ideally Suited to Marine Environment
● Cable and Connector Approvals
– NMEA 2000, IEC 61162-3, Lloyds
● 3 Cable Sizes(Micro, Mid, Mini)
– Micro and Mid Use Same Connectors
– All Use Same 5 Wire Color Coding
– All Cabling Systems are 12 Volt
– Micro Cable
– Small/Short Networks(<10 Nodes)
– Rated to 4 Amps
– Voltage Drops of Concern- Mid Cable(ABYC Approved)
– Mid/Large Networks
– Rated to 4 Amps- Mini Cable(ABYC Approved)
– Large Networks
– Rated to 8 Amps.
Micro Cables and Connectors
● Micro Bulk Cable
– Three Levels of Shielding, Data Pair, Power Pair, and Overall
– 22 Gauge Power Pair Rated to 4 Amps
– Micro/Mid Field Attachable Connectors
– Used With Bulk Cable to Build Cordset
– Color Coded Screw Terminals Match Wire Colors for Error Free Installation
● Micro/Mid 90° Field Attachable Connectors
– Used for Tight Corners(i.e., Behind Displays)
● Micro Double-Ended Cordsets
– Waterproof to IP68(Submersible)
– Available in Various Lengths(0.5 to 10 Meter)
● Micro/Mid Tee
– Used to Insert Cable Drop to Electronic Product
– Keyed Connectors for Error Free Connections
● Micro/Mid Power Tap Tee
– Two 18 Gauge Power Pairs for Feeding 4 Amps to Both Sides of Network
– Meets ABYC Minimum Power Gauge Wire Size Requirements
● Micro/Mid Termination Resistors
– Available in Both Male and Female Genders
– Inline Terminator Used Where Network Terminated at Product(i.e., Top of Mast at Wind Sensor)
● Micro/Mid Bulk Head Feed-Thru
– Used to Maintain Watertight Integrity Through Bulk heads
● Micro/Mid Multiport Box
– Used for Congested Product Areas(i.e., Under Helm)
– Used with Double-Ended Cordset for Multiport Feed and Drops.
– Three Levels of Shielding, Data Pair, Power Pair, and Overall
– 22 Gauge Power Pair Rated to 4 Amps
– Micro/Mid Field Attachable Connectors
– Used With Bulk Cable to Build Cordset
– Color Coded Screw Terminals Match Wire Colors for Error Free Installation
● Micro/Mid 90° Field Attachable Connectors
– Used for Tight Corners(i.e., Behind Displays)
● Micro Double-Ended Cordsets
– Waterproof to IP68(Submersible)
– Available in Various Lengths(0.5 to 10 Meter)
● Micro/Mid Tee
– Used to Insert Cable Drop to Electronic Product
– Keyed Connectors for Error Free Connections
● Micro/Mid Power Tap Tee
– Two 18 Gauge Power Pairs for Feeding 4 Amps to Both Sides of Network
– Meets ABYC Minimum Power Gauge Wire Size Requirements
● Micro/Mid Termination Resistors
– Available in Both Male and Female Genders
– Inline Terminator Used Where Network Terminated at Product(i.e., Top of Mast at Wind Sensor)
● Micro/Mid Bulk Head Feed-Thru
– Used to Maintain Watertight Integrity Through Bulk heads
● Micro/Mid Multiport Box
– Used for Congested Product Areas(i.e., Under Helm)
– Used with Double-Ended Cordset for Multiport Feed and Drops.
Mini Cables and Connectors
● Mini Bulk Cable(Gray and Blue)
– Three Levels of Shielding, Data Pair, Power Pair, and Overall
– 15 Gauge Power Pair Rated to 8 Amps
● Mini Field Attachable Connectors
– Used With Bulk Cable to Build Cordsets
– Color Coded Screw Terminals Match Wire Colors for Error Free Installation
● Mini Double-Ended Cordsets
– Waterproof to IP68(Submersible)
– Available in Various Lengths(0.5 to 10 Meter)
● Mini Double-Ended Cordsets
– Waterproof to IP68(Submersible)
– Available in Various Lengths(0.5 to 10 Meter)
● Mini Tees
– Used to Insert Cable Drop to Electronic Product
– Keyed Connectors for Error Free Connections
● Mini Power Tap Tee
– Independent Left and Right Network Fuses
– 16 Amp Feed – 8 Amps to Left and 8 Amps to Right
● Mini Termination Resistors
– Available in Both Male and Female Genders
– Available With Diagnostic LEDs
● Mini 90° Elbow
– Used for Tight Corners
● Mini to Micro/Mid Reducer
– Used to Change Cable Sizes(i.e., Mini Backbone to Mid Cable for Running Up Mast)
● Mini Gender Changers
– Available in Both Male and Female Genders
● Mini Bulk Head Feed-Thru
– Used to Maintain Watertight Integrity Through Bulk heads
● N2KMeter
– Cable and Connector Diagnostic Tool
– 250 Test Automatically Run When Plugged Into Network with Easy to Understand Results
– Data Can be Logged and Locked Into Unit for Later Analysis by Trained Personnel.
– Three Levels of Shielding, Data Pair, Power Pair, and Overall
– 15 Gauge Power Pair Rated to 8 Amps
● Mini Field Attachable Connectors
– Used With Bulk Cable to Build Cordsets
– Color Coded Screw Terminals Match Wire Colors for Error Free Installation
● Mini Double-Ended Cordsets
– Waterproof to IP68(Submersible)
– Available in Various Lengths(0.5 to 10 Meter)
● Mini Double-Ended Cordsets
– Waterproof to IP68(Submersible)
– Available in Various Lengths(0.5 to 10 Meter)
● Mini Tees
– Used to Insert Cable Drop to Electronic Product
– Keyed Connectors for Error Free Connections
● Mini Power Tap Tee
– Independent Left and Right Network Fuses
– 16 Amp Feed – 8 Amps to Left and 8 Amps to Right
● Mini Termination Resistors
– Available in Both Male and Female Genders
– Available With Diagnostic LEDs
● Mini 90° Elbow
– Used for Tight Corners
● Mini to Micro/Mid Reducer
– Used to Change Cable Sizes(i.e., Mini Backbone to Mid Cable for Running Up Mast)
● Mini Gender Changers
– Available in Both Male and Female Genders
● Mini Bulk Head Feed-Thru
– Used to Maintain Watertight Integrity Through Bulk heads
● N2KMeter
– Cable and Connector Diagnostic Tool
– 250 Test Automatically Run When Plugged Into Network with Easy to Understand Results
– Data Can be Logged and Locked Into Unit for Later Analysis by Trained Personnel.